POWERUT TG-IL uses Dry-Coupled UT (DCUT) sensors to measure thickness of metallic and non-metallic materials with optimum lateral resolution and accuracy.
Features
Proprietary DCUT sensors with no-couplant.
Ambient temperature inspection.
Wheel and touch probe sensors for continuous and spot measurements.
Great accuracy (+/-2.5µm) and lateral resolution (1mm).
Thickness readings (lateral resolution) of 1mm at 2m/s.
Automatic calculation of eccentricity and ovality.
Thickness measurement on internally tapered tubes.
Applicable to finishing lines on tubes (stainless, carbon), pilger mills and many other applications.
Materials Inspected: – Metallic and non-metallic materials including most plastics and composites. – Minimum thickness: 1mm (0.039”) contact Innerspec for thinner material – Surface temperature: from -10ºC (14ºF) to 200ºC (392ºF)
Sensor Head Assembly: – Touch probe and wheel options for scanning applications. – Non-marring rubber coupling. – Designed for easy attachment to different mountings.
Instrumentation: – Strip, plate and tube thickness measuring instrument called PRIMO SC. – IP54 industrial enclosure can be located up to 2m from point of inspection. – Different enclosures can handle from 1 to 8 channels simultaneously. – 1 Channel Enclosure. Dimensions: 252mm L x 169mm W x 57mm T. Weight: 1.5Kg – Accessible by any device connected to the instrument’s IP address via WiFi or Ethernet.